LOAD FRAME MOTORISED CAPACITY 50KN HAVING 8 SPEEDS.
It has the following features:
Two Pillar
type.
Detachable Frame.
Enclosed Motor and Gear
System.
Indicator.
Speed Chart.
Useful in Triaxial and C.B.R.
test.
It consists of a
cabinet which housed the electrical mortor, reduction
gear and the turret gear box. The loading is done
by the upward movement of the lower platen which is
firmly fixed to the lead screw. When the lever is
set in the neutral position, it isolates the lead
screw from the rest of the drive mechanism, and the
lead screw can then be manually moved up or down by
operating the handle.
A main switch, an indicator and a forward reverse
switch are fixed on the unit. A relay is fitted inside
the cabinet so that in case of power failure,
the unit will not restart of its own on the
resumption of power,unless the switches are
operated.
The adjustable crosshead can be set at any desired
position or height over the two pillars and
secured in position by tightening the adjustment
nut. It carried a hexagonal proving ring adaptor.A
bracket for strain dial gauge is attached to
one of the pillars of the load frame.
It
rates of strain are 0.025mm./min, 0.05mm/min,
0.05mm/min, 0.0625, 0.125mm/min, 0.025mm./min,0.025mm./min,
0.5mm/min., 0.625mm./min. and 1.25mm./min.
Suitable operation
on 230volts Suitable operation on 230 volts, 50
cycles, single phase, A.C. supply.
Note:
The above model is also available in 30 rates
of strain and in 20KN capacity with 6 rates of
strain.
LOAD
FRAME MOTORISED CAPACITY 50KN WITH 3 RATES
OF STRAIN.
It has the following features:
Two Pillar type.
Detachable
Frame.
Enclosed Motor
and Gear System.
Indicator.
Speed Chart.
Useful in
Triaxial and C.B.R. test.
It consists of a cabinet which housed
the electrical motor, reduction gear.
The loading is done by the upward movement
of the lower platen which is firmly
fixed to the lead screw. When the lever
is set in the neutral position, it isolates
the lead screw from the rest of the
drive mechanism, and the lead screw
can then be manually moved up or down
by operating the handle.
A main switch, an indicator and a forward
reverse switch are fixed on the unit.
A relay is fitted inside the cabinet
so that in case of power
failure, the unit will not restart
of its own on the resumption of
power, unless the switches are
operated.
The adjustable crosshead can be
set at any desired position or
height over the two pillars and
secured in position by tightening
the adjustment nut. It carried
a hexagonal proving ring adaptor.
A bracket for strain dial gauge
is attached to one of the pillars
of the load frame. Its rates of
strain are 2.5mm./min, 1.5mm/min
and 1.25mm./min.